Brightness, comparison, smooth, sharp,
gray, stretch, equalize, etc.
IOL Table Calculate
SRK-Ⅱ, SRK-T, Hoffer-Q, Holladay, SCDK, Halgis.
TECHNICAL PARAMETERS
B Scan
A Scan
Scan Mode
Sector
Probe Frequency
10MHz
Scan Angle
53°
Measurement Accuracy
≤0.04mm
Detect Depth
≥50mm
Measure
ACD, Lens, Vitreous, Axial Length
and its average
Probe Frequency
10MHz
Scan Line
512 Lines
Modes
Manual, Automatic
Gray Scale
256
Data processing Results
IOL Parameter Selection Table
Display Model
B, B+B, B+A
Output Mode
Laser Printer
Image Storage
Freeze 10 images
Image Post
Processing
Brightness, comparison, smooth, sharp,
gray, stretch, equalize, etc.
IOL Table Calculate
SRK-Ⅱ, SRK-T, Hoffer-Q, Holladay, SCDK, Halgis
]]>https://medicalmarketbd.com/product/ophthalmic-a-b-scan/feed/0Projection Perimeter
https://medicalmarketbd.com/product/projection-perimeter/
https://medicalmarketbd.com/product/projection-perimeter/#respondTue, 04 Aug 2020 10:25:13 +0000http://medicalmarketbd.com/?post_type=product&p=6749
Model
APS-T90
APS-T00
Appearance
Split type
Integrated Type
Stimulating way
Optical projection
Projection surface
aspheric projection arc
Detection method
Static perimetry, Dynamic Perimetry
Detection scope
0-90°
Brightness Level
0-51db
Testing Distance
300mm
Visual Target Color
Red, Blue, White
Visual Target Brightness
0asb-10000asb
Background Light
White(31.5asb),yellow(315asb )
Vision Target Interval time,
keeping time
Patients adaptive, standard, slow, custom
Pupil Size Measurement
Auto
Head Movement Way
AEC Eye position monitoring and automatic correction system
Brightness Measurement
Brightness Auto Measurement and correction
Visual Target Size
(Goldmann standard)
G r a d e Ⅱ G r a d e Ⅲ G r a d e Ⅳ G r a d e Ⅴ G r a d e
Detection strategy
Full-threshold, fast threshold, custom, Two notation,
three notation,quantify defects,Intelligent dynamic, fast intelligent dynamic
Threshold policy
age-related, threshold-related, single strength
Static
Perimetry
Threshold
Test Mode
Center 10-2,Center 24-2,Center 30-2,Center60-4,Nasal step,macula;
Screening,
special test mode
Center 40,Center 64,Center 76;Center80,Center Armaly,Peripheral 60,
Nasal step,Armaly Full Field,Full Field 81,Full Field 120,Full Field1 35,
Full Field246,upper36,upper64,Esterman monocular,Estermanbinocular
Dynamic
Perimetry
dynamic
program
manual procedures, standard procedures (Standard 45, standard 30, a high-resolution 15),
Static point map, dark spot map, blind spot map, custom scan, custom dynamic program
Value map, grayscale map , the overall bias decibel chart,
The overall deviation probability map, chart pattern deviation decibels,
Pattern deviation probability plot, staring Figure
]]>https://medicalmarketbd.com/product/projection-perimeter/feed/0Fundus Camera & Fluorescein Fundus Angiography
https://medicalmarketbd.com/product/fundus-camera-fluorescein-fundus-angiography/
https://medicalmarketbd.com/product/fundus-camera-fluorescein-fundus-angiography/#respondTue, 04 Aug 2020 10:16:15 +0000http://medicalmarketbd.com/?post_type=product&p=6728
Adopts the fifth generation leading optical system in China
Professional high definition SLR digital camera, up to 24.1 mega pixels
Manual focus, manual flash, auto image optimization
Automatic jigsaw, seamless splicing pictures, presenting the whole retinal image
Fundus color image, fluorescence fundus fluorography.
The smallest pupil is 3.3mm, and the audience is larger, which is suitable for the ophthalmological examination, physical examination and diabetic fundus screening.
The fundus color images, the dynamic images and static flash of fluorescence angiography of the retina were treated in a digital manner.
The image can be processed, arbitrarily zooming, moving, pasting, splicing, measuring and calculating the area of the lesion, the editing of the text and the digitization of the generated medical records.
]]>
Adopts the fifth generation leading optical system in China
Professional high definition SLR digital camera, up to 24.1 mega pixels
Manual focus, manual flash, auto image optimization
Automatic jigsaw, seamless splicing pictures, presenting the whole retinal image
Fundus color image, fluorescence fundus fluorography.
The smallest pupil is 3.3mm, and the audience is larger, which is suitable for the ophthalmological examination, physical examination and diabetic fundus screening.
The fundus color images, the dynamic images and static flash of fluorescence angiography of the retina were treated in a digital manner.
The image can be processed, arbitrarily zooming, moving, pasting, splicing, measuring and calculating the area of the lesion, the editing of the text and the digitization of the generated medical records.
Battery :Rechargeable lithium batteries, 6 hours of duration, Replaceable
Size:180mm×130 mm×110mm
Display: 5 inch touch screen
Weight:0.8Kg
Optional accessories: Camera tripods, printer, etc
]]>
Operation mode: Bino/Mono
Optometry: Automatic
DS:Range:-7.50D~+7.50D
Resolution:0.25D/0.01D
Accuracy:±0.50D
DC:Range:0.00D~3.00D
Resolution:0.25D/0.01D
Accuracy:±0.50D
Axis: Range:1°~180°
Resolution:1°
Accuracy:±5°
Pupil size:Range :4.0 mm~9.0 mm
Resolution :0.1mm
Accuracy :±0.1 mm
Pupil distance:Range :35 mm~80 mm
Resolution:1mm
Accuracy:±1 mm
Gaze:0°~ 20°
Measuring distance:1 m ± 5 cm
Time per measurement: ~1s
Fixation target: Light flash, attractive sound
Data interface: Wi-Fi,USB
Printer interface: USB
Battery :Rechargeable lithium batteries, 6 hours of duration, Replaceable
Size:180mm×130 mm×110mm
Display: 5 inch touch screen
Weight:0.8Kg
Optional accessories: Camera tripods, printer, etc
]]>https://medicalmarketbd.com/product/vision-screener-model-sw-800/feed/0Slit Lamp(5-Step)
https://medicalmarketbd.com/product/slit-lamp5-step/
https://medicalmarketbd.com/product/slit-lamp5-step/#respondTue, 04 Aug 2020 10:04:40 +0000http://medicalmarketbd.com/?post_type=product&p=6745
Large view range, high magnification, good scalability
Five-step drum zoom design, easier to use
Maximum 14mm spot checks greater extent of disease
21.5mm high eye point more comfortable to check
All optical lens are made from import materials, carried out moisture proof, mould proof and coating process, which prove its good optical performance in different weather condition
High quality micro-positioning platform, easy to operate
Reserved digital upgrade interface, you can upgraded to a digital slit lamp
]]>
Model
SLM-2ER-L
Microscope Type
Galileo Parallel
Magnifications change way
Drum Five Magnifications
Eyepiece Magnification
12.5x
Total Magnifications
6X 10X 16X 25X 40X
Diopter Adjustment
-5D ~ +5D
Illumination
Three Steps (Stepless Optional)
Slit Width
0-14mm Continuous
Slit Height
1-14mm Continuous
Slit Angle
0°-180° Adjustable
Slit Inclination Angle
5° 10° 15° 20°
Light Source
Light Spot Diameter
0.2mm,1mm,2mm,5mm,10mm,14mm
Filter
Heat Absorption;Grey;Redfree;Cobalt Blue
Fixation
Red LED
Electrical
Illumination Bulb
German Osram Halogen Tungsten Lamp
Led Lamp (Optional)
Input Voltage
110V/220V(±10%)
Input Power
60VA
Diffuse Lens
Yes
Preset Lens
Yes
Laser Interface
Optional
Applanation Tonometer Interface
Yes
Base Movement
X: 100mm ± 3
Y: 75mm ± 3
Z: 30mm ± 3
]]>https://medicalmarketbd.com/product/slit-lamp5-step/feed/0Slit Lamp(3-Step)
https://medicalmarketbd.com/product/slit-lamp3-step/
https://medicalmarketbd.com/product/slit-lamp3-step/#respondTue, 04 Aug 2020 10:01:28 +0000http://medicalmarketbd.com/?post_type=product&p=6743
Large view range, high magnification, good scalability
Three-step drum zoom design, easier to use
Maximum 14mm spot checks greater extent of disease
21.5mm high eye point more comfortable to check
All optical lens are made from import materials, carried out moisture proof, mould proof and coating process, which prove its good optical performance in different weather condition
High quality micro-positioning platform, easy to operate
Reserved digital upgrade interface, you can upgraded to a digital slit lamp
]]>
Model
SLM-2ER-L
Microscope Type
Galileo Parallel
Magnifications change way
Drum Three Magnifications
Eyepiece Magnification
12.5x
Total Magnifications
10X 16X 25X
Diopter Adjustment
-5D ~ +5D
Illumination
Three Steps (Stepless Optional)
Slit Width
0-14mm Continuous
Slit Height
1-14mm Continuous
Slit Angle
0°-180° Adjustable
Slit Inclination Angle
5° 10° 15° 20°
Light Spot Diameter
0.2mm,1mm,2mm,5mm,10mm,14mm
Filter
Heat Absorption;Grey;Redfree;Cobalt Blue
Fixation
Red LED
Electrical
Illumination Bulb
German Osram Halogen Tungsten Lamp
Led Lamp (Optional)
Automatically print the English Report with curve picture.
Big amount of data storage (for selection).
Bluetooth model (for selection).
Function of data analyzing and solution.
]]>It is the dedicated equipment for the lower urinary tract dysfunction test of Urology Dept.
Working Principal:
sensor and world class controlling technology. By means of microcomputer to analyze the data from sensor. It can supply speedy and convenient test of urine flow rate items. The measuring data and technology is comply with the requirement of International Continence Society (ICS.).
Range of Applications:
It is mainly used for measuring patient’s voiding process parameter (Volume quantity, urine flow rate) and curve of process. The data will be supplied to the doctor for evaluation of patient’s lower urinary function and diagnose the lower urinary obstruction or make it as reference of treating method. Evaluate the treating effect.
Clinical Advantage:
The different installation measuring system can be supplied by different requirement of user.
The parameter will be measured automatically, intelligent measuring start, whole course urine flow rate curve, 2.0 USB interface (computer model for selection).