Brand
YZ
Model NO
YZ-200B
Type
X-Ray Equipment
Group
Infants and Young Children
Medical devises Reg./Record No
Su20010304
Transport Package
Wooden case
Origin
Jiangsu, china
]]>
Brand
RMS
Place of Origin
India
Model
YXK-5GB
mA
500
KV
125
X-Ray Generator
40 KW
Manual Tilt
5 position
Stand
Floor to Ceiling
Overload Protection
Electronic
Tube
Bel or Toshiba
| Category | Specifications |
| Tube | E7252X Focal spots: 0.6mm small (27kW) 1.2mm large (75kW) Anode heating unit: 300kHU Max. kV: 150kV Housing heat unit: 1250kHU |
| Tube stand | Type: Floor mounted with counterbalanced. Electromagnetic locks Travel ranges : Longitudinal : 180cm Vertical : 149cm (40 to 189cm from the floor level) Transverse : 24cm Tube arm angle : Horizontal axis : -90° ~ +90° Vertical axis : -90° ~ +90° LCD screen to display tube angle status. |
| Collimator | Type: manual Filtration : 0.1/0.2mm cooper & Aluminum – auto choice available by APR Exposure area to be identified through halogen light |
HF-525 Plus includes
Dose Efficiency :
The efficiency of X-ray quantum detection is a function of the number of X-rays that reach the absorbed detector. Higher-quantity output systems can produce images of higher quality, at a lower dose.
Robust Design & Technology :
HF-525 Plus offers high-level conveniences for operators who handle different examinations of the tube and table positions. With Smart Positioning Mechanism
Operation Console
High-Frequency Generators
50kW/65kW Generator
Optional
80kW Generator (150kV / 1000mA / 500mAs)
Optional
Radiographic Table
Wall Stand
| Generator | DRE140 |
| Max. Output | 40kW |
| mA range | 10 ~ 500mA |
| kV range | 40 ~ 125kV |
| mAs range | 0.4 ~ 630mAs |
| Power supply | 1Ø 220VAC 50/60Hz |
| Exposure time | 0.004 ~ 10sec |
| No. of APR | 216 |
| Option | AEC |
| X-ray tube | DRE140 |
| Focal spot | 1.0/2.0mm |
| Anode heat capacity | 100kJ (140kHU) |
| Target angle | 16° |
| Voltage range | 40 – 125kV |
| Weight | 16kg |
| Permanent filtration | 0.9mmAl |
| Flat panel detector | DRE140 |
| Scintillator | CSI |
| Pixel pitch | 143um |
| Resolution | 3.7lp/mm |
| MTF | 36% (2.0lp/mm, 70kVp, 1×1) |
| DQE | 0.7 |
| Active Area | 43 x 43.9cm |
| Pixel matrix | 3,008 x 3,072 |
| AD conversion | 14 bits |
| Energy range | 40 ~ 150kVp |
| Power supply | 1Ø 100 ~ 240VAC 50/60Hz |
| Dimension | 512 x 495 x 43mm |
| Weight | 16kg |
| Flat panel detector | DRE140 |
| Scintillator | CSI |
| Pixel pitch | 143um |
| Resolution | 3.7lp/mm |
| MTF | 36% (2.0lp/mm, 70kVp, 1×1) |
| DQE | 0.7 |
| Active Area | 43 x 43.9cm |
| Pixel matrix | 3,008 x 3,072 |
| AD conversion | 14 bits |
| Energy range | 40 ~ 150kVp |
| Power supply | 1Ø 100 ~ 240VAC 50/60Hz |
| Dimension | 512 x 495 x 43mm |
| Weight | 16kg |
| Collimator | DRE140 |
| Power supply | 1Ø 24VAC 50/60Hz |
| Max. kVp shield | 35 x 35cm at SID 65cm |
| Inherent filtration | 1.2mmAl |
| Lamp luminosity | Over 160Lux |
| Lamp time | 30sec |
| Field size control | Manual |
| Vertical travel distance | 1,400mm |
| Transverse travel distance | 260mm |
| Min. Tube height (from the floor) | 550mm |
| Max. Tube height (from the floor) | 1,950mm |
| Column rotation | ±90° |
| Tube rotation | ±180° |
| Longitudinal travel distance | 2,400 ~ 3,000mm ,(floor-ceiling fixed type), 1,500mm (floor fixed type) |
| Power supply | 24VDC, 3A |
| Weight | DRE140/150 |
| Vertical travel distance | 1,400mm |
| Min. Tube height (from the floor) | 400mm |
| Max. Tube height (from the floor) | 1,800mm |
| Power supply | 1Ø 16 ~ 24VAC 50/60Hz |
| Weight | 120kg |
| Application | DRE140/150 |
| Tabletop size | 2,000 x 745mm |
| Tabletop height | 670mm |
| Tabletop material | Acryl |
| Longitudinal Travel distance | ±280mm |
| Transverse travel distance | ±140mm |
| Bucky travel distance | ±230mm |
| Max. patient weight | Max. 150kg |
| Power supply | 1Ø 220VAC 50/60Hz |
| Weight | 160kg |
| Application | DRE140/150 |
| Components | DRE140 with fixed dual FPD | DRE140 with portable FPD |
| 40kW Generator | ok | ok ok |
| 50kW Generator | ||
| 17″ x 17″ Flat panel detector | ok | |
| 14″ x 17″ Flat panel detector | ok | |
| 150kV X-ray tube | ||
| 125kV X-ray tube | ok | ok ok |
| Basic Configuration | Tube stand, Bucky stand, Bucky table, PC & monitor, Acquisition Software,- upgradable to floor mounted Tube stand,- for international sales |
By using a quick and easy-to-use interface, ExamVue software provides an extensive collection of X-ray image analysis instruments. The example provides features for high-performance image processing and measuring.
X-ray Generator
High-frequency generator guarantees a minimal dose of the patient, outstanding reproducibility and superior contrast of the picture.
Flat panel detector
For digital radiographic applications, flat panel detector provides high sensitivity, high resolution, low noise, and excellent image quality. There are infinite clinical applications for portable flat panel detector.
Tube stand
Ergonomically designed pipe stand for table and stand examinations offers the operator with quicker and easier motion.
Bucky stand
Wide range of vertical travel (400 ~ 1,800 mm) enables exposures from the cervical spine to the lower limbs.
Bucky table
The robust table design makes it possible to examine obese patients with a table weight of up to 150 kg. The operator can take care of the patient securely without any unexpected tabletop motion due to the footswitch incorporated into a stable foundation.
The scheme can be used as a dual detector scheme 17 “X 17” or as a single detector scheme 14 “X 17.”
]]>| Item | Content | |
| Radiography | Tube voltage | 44-125kV |
| Tube current | 32~500mA | |
| Exposure time | 0.02-5s adjustable by steps | |
| SC4-1 | adjustable by steps Tabletop dimension | 0.02-5s |
| mm Tabletop longitudinal movement | 2000x730x690 | |
| Tabletop transverse movement | 1200mm | |
| Lock mode | Electromagnetic | |
| lock Tube stand longitudinal movement | 580mm | |
| Tube stand vertical movement | 1100mm | |
| Rotation around lateral arm | 0 | |
| Bucky | Fixed | |
| X-ray Tybe assembly | Model | XD52-30,50/125 |
| Focus | 1×1/2x2mm Power | |
| Power | 30kW/50kW | |
| Speed | 2800r/min | |
| Grid | Manual | |
| Power | Voltage | 380V + 10% Frequency |
| Frequency | 50HZ + 1Hz | |
| Inner resistance | 0.322 |
Programmable radiographic features, including 90 radiographic memory programs. The parameters can be manually chosen, too.
X-ray tube protection:
X-ray tube heat and load capacity are controlled and protected by computer programs so that tube efficiency and radiographic parameters can be used to the limit.
Selection of anatomical exposure:
Parameters of exposure may be set based on the size of the patient and location of exposure. It is also possible to correct and store the parameters.
Safety function:
The self-diagnostic error method can quickly and accurately assess the problems. It can automatically execute security and view error code.
Tabletop longitudinal movement Tube lock mode Longitudinal movement Tube stand vertical movement Rotation around the sidearm Bucky Tabletop longitudinal movement Lock movement
]]>