DRE 140 X-ray machine 500MA

DRE 140 X-ray machine 500MA

PRODUCT ID: Winux_0115
Generator DRE140
Max. Output 40kW
mA range 10 ~ 500mA
kV range 40 ~ 125kV
mAs range 0.4 ~ 630mAs
Power supply 1Ø 220VAC 50/60Hz
Exposure time 0.004 ~ 10sec
No. of APR 216
Option AEC
X-ray tube DRE140
Focal spot 1.0/2.0mm
Anode heat capacity 100kJ (140kHU)
Target angle 16°
Voltage range 40 – 125kV
Weight 16kg
Permanent filtration 0.9mmAl
Flat panel detector DRE140
Scintillator CSI
Pixel pitch 143um
Resolution 3.7lp/mm
MTF 36% (2.0lp/mm, 70kVp, 1×1)
DQE 0.7
Active Area 43 x 43.9cm
Pixel matrix 3,008 x 3,072
AD conversion 14 bits
Energy range 40 ~ 150kVp
Power supply 1Ø 100 ~ 240VAC 50/60Hz
Dimension 512 x 495 x 43mm
Weight 16kg
Flat panel detector DRE140
Scintillator CSI
Pixel pitch 143um
Resolution 3.7lp/mm
MTF 36% (2.0lp/mm, 70kVp, 1×1)
DQE 0.7
Active Area 43 x 43.9cm
Pixel matrix 3,008 x 3,072
AD conversion 14 bits
Energy range 40 ~ 150kVp
Power supply 1Ø 100 ~ 240VAC 50/60Hz
Dimension 512 x 495 x 43mm
Weight 16kg
Collimator DRE140
Power supply 1Ø 24VAC 50/60Hz
Max. kVp shield 35 x 35cm at SID 65cm
Inherent filtration 1.2mmAl
Lamp luminosity Over 160Lux
Lamp time 30sec
Field size control Manual

Tube Stand:

Vertical travel distance 1,400mm
Transverse travel distance 260mm
Min. Tube height (from the floor) 550mm
Max. Tube height (from the floor) 1,950mm
Column rotation ±90°
Tube rotation ±180°
Longitudinal travel distance 2,400 ~ 3,000mm ,(floor-ceiling fixed type), 1,500mm (floor fixed type)
Power supply 24VDC, 3A
Weight DRE140/150

Bucky Stand:

Vertical travel distance 1,400mm
Min. Tube height (from the floor) 400mm
Max. Tube height (from the floor) 1,800mm
Power supply 1Ø 16 ~ 24VAC 50/60Hz
Weight 120kg
Application DRE140/150

Bucky Table:

Tabletop size 2,000 x 745mm
Tabletop height 670mm
Tabletop material Acryl
Longitudinal Travel distance ±280mm
Transverse travel distance ±140mm
Bucky travel distance ±230mm
Max. patient weight Max. 150kg
Power supply 1Ø 220VAC 50/60Hz
Weight 160kg
Application DRE140/150

Configuration of The System:

Components DRE140 with fixed dual FPD DRE140 with portable FPD
40kW Generator ok ok ok
50kW Generator
17″ x 17″ Flat panel detector ok
14″ x 17″ Flat panel detector ok
150kV X-ray tube
125kV X-ray tube ok ok ok
Basic Configuration Tube stand, Bucky stand, Bucky table, PC & monitor, Acquisition Software,- upgradable to floor mounted Tube stand,- for international sales

Share:

Operation Software

By using a quick and easy-to-use interface, ExamVue software provides an extensive collection of X-ray image analysis instruments. The example provides features for high-performance image processing and measuring.

X-ray Generator

High-frequency generator guarantees a minimal dose of the patient, outstanding reproducibility and superior contrast of the picture.

Flat panel detector

For digital radiographic applications, flat panel detector provides high sensitivity, high resolution, low noise, and excellent image quality. There are infinite clinical applications for portable flat panel detector.

Tube stand

Ergonomically designed pipe stand for table and stand examinations offers the operator with quicker and easier motion.

Bucky stand

Wide range of vertical travel (400 ~ 1,800 mm) enables exposures from the cervical spine to the lower limbs.

Bucky table

The robust table design makes it possible to examine obese patients with a table weight of up to 150 kg. The operator can take care of the patient securely without any unexpected tabletop motion due to the footswitch incorporated into a stable foundation.

The scheme can be used as a dual detector scheme 17 “X 17” or as a single detector scheme 14 “X 17.”